A sitting hyperbaric chamber gives you a seated or semi-reclined position, while a lying chamber uses a horizontal layout. Compare how you will get in and out, the clear floor depth and ceiling height, and the rated ATA for the exact model. Keep laptops, tablets, lighters, and other ignition sources outside either chamber, and arrange for someone to stay nearby and supervise whenever it is in use. MACY-PAN home chamber guidance
“Sitting,” “seated,” and “sit-up” generally describe a chamber arranged for a chair or an upright or semi-reclined posture. Some seated designs have a sloping shell with a longer base. If a listing says “vertical hyperbaric chamber,” use the drawing to see how upright the unit actually is and where the opening sits. A lying type hyperbaric chamber is laid out so the user can lie along its length. Read the model’s ATA rating separately from its posture and shape. MACY-PAN seated chamber range · MACY-PAN soft lying chamber range
Measure the space in the orientation in which the chamber will sit. Floor depth is the usable distance in the direction of the chamber’s long side. Clear height is the distance to the lowest obstruction above the proposed layout, such as a beam, shelf, or sloping ceiling. Mark the entry side and leave room there for the user and the person supervising.
Two MACY-PAN capsules illustrate the trade-off. The ST1700 seated capsule is listed at 170 × 70 × 110 cm, or about 67 × 28 × 43 in. The ST901 lying capsule is listed at 225 × 90 × 90 cm, or about 89 × 35 × 35 in. The ST1700 example is about 22 inches shorter and 8 inches taller. Use these published capsule dimensions for an initial room sketch. Ask for an installed drawing showing the frame or base, fittings, separate equipment, and required access clearances before using either figure as a fit decision. ST1700 product dimensions · ST901 product dimensions
| Room check | Seated layout | Lying layout |
|---|---|---|
| Floor depth | Allow for the full base and any reclining position shown in the layout drawing. | Measure along the full chamber length and include working space at the actual entry. |
| Clear height | Measure above the tallest part of the installed chamber and above the approach where the user moves into position. | Measure above the capsule and any fittings, and along the route where the user and attendant approach. |
| Entry clearance | Ask for the usable opening size, entry height, seat height, and space needed next to the opening. | Ask where the opening sits and how much side or end space is required to enter, turn, and lie down. |
| Equipment and supervision | Mark locations for all accessories and a clear position from which the attendant can supervise and reach the controls. | Mark the same spaces and check that the layout leaves the entry and controls accessible throughout use. |
Ask the supplier for an entry demonstration for the exact model. Compare the height of the opening and the movement required once inside. A seated design may involve lowering onto a chair, while a lying design may involve getting down to a lower surface and then standing again. Give the supplier the entry-side clearance and explain the movements the intended user can comfortably make. Confirm what assistance the manufacturer’s instructions require.
If the footprint seems close, mark the chamber outline and doorway or zipper location with tape on the floor. Walk the approach and check that furniture, open doors, and accessory units leave a clear path. Send the sketch to the supplier with the ceiling measurement and ask them to identify any additional space needed.
Leave laptops, tablets, phones, lighters, and other ignition sources outside the chamber. Bring only items permitted by the instructions for the exact model. Ask for the current manual before ordering and check its rules on clothing, accessories, and any personal item you need to bring. Arrange for someone outside the chamber to stay nearby and supervise throughout use, following the instructions for that model. MACY-PAN home chamber safety guidance
Start with the entry position and room measurements you have collected. Browse the seated chamber range or the soft lying chamber range for layouts that fit those requirements. The MACY-PAN home chamber page brings the home configurations and safety guidance together.
It may take up less floor depth than a particular lying chamber. Compare the installed length and height, the space at the entry, and the location of auxiliary equipment on both drawings. The shorter capsule can still require more clear height or approach space.
Use the minimum installation clearance specified for the exact model. Measure to the lowest beam, shelf, or other obstruction above both the chamber and its entry. Ask the supplier to include the installed base and fittings in the drawing.
The rated ATA comes from the specific chamber and pressure configuration. For either posture, ask for the nominal operating pressure on the model’s specification sheet and check that the same configuration appears on the quote.
Use a cushion or blanket only if the exact model’s instructions permit it. If the manual gives requirements for the material or accessory, check the item against those requirements with the supplier before using it. MACY-PAN home chamber safety guidance
Discount Price, ship by DHL, door to door service, 5-7days delivery time, local technical support
We supply soft and hard chambers from 1.3-2.0ATA to reach different customers' needs
Create custom uniquea hyperbaric chambers to reach your target market
We have more than 50 distributors around world, looking forward to having you on board.